Stamina Zone emergency light TWS5292WMS

Self-contained Emergency light with 1 h Escap super capacitor, Lumi Test self-testing and a light sensor

Stamina Zone is designed to meet the highest demands in challenging environments.

The luminaire has an impact resistant IK10 metal body and is both dustproff and water-resistant (IP65). The Escap supercapacitator enables the luminaire to function even in freezing temperatures down to -25°C (-13°F). The Stamina has several mounting options, and can also be used as a 300 lumen general light when connected to the mains.

The TWS5292WMS is equipped with an adjustable light sensor that switches off the general lighting mode whenever the ambient light exceeds a set luminance in the range 10-600 lux.

1 h
icon-ce
EN 1838
EN 60598_2_22
icon-Escap
850 °C
65
icon-LED
icon-LumiTest
220-240 V 50/60 Hz AC
icon-ProtectionClassI
9007
icon-Through-wiring
Product codeTWS5292WMSElectrical number (FI)4148746
GTIN06438045028361TARIC code94056180
Weight1,40 kgMeasurements265 × 100 × 87 mm
Backup (h)1 hBody materialcast aluminium
CE MarkYesColourRAL9007 (Grey aluminium)
Electrical Installation3/4 x 2,5 mm²EN 1838Yes
EN 60598-2-22YesEscapYes
ETIM classEmergency luminaire (EC001957)Glow Wire Test of Plastic Materials (°C)850
IP ClassIP65Light SourceLED
Lumi TestYesLuminous Flux (lm)32
Max Input Power VA11 VA / 3 VAMountingCeiling, Wall
Nominal Supply Voltage220-240 V, 50/60 Hz ACProtection ClassI
Temperature Range Min - Max (°C)-25...+35Suitable for Through-WiringYes
Product codeTWS5292WMS
Electrical number (FI)4148746
GTIN06438045028361
TARIC code94056180
Weight1,40 kg
Measurements265 × 100 × 87 mm
Backup (h)1 h
Body materialcast aluminium
CE MarkYes
ColourRAL9007 (Grey aluminium)
Electrical Installation3/4 x 2,5 mm²
EN 1838Yes
EN 60598-2-22Yes
EscapYes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850
IP ClassIP65
Light SourceLED
Lumi TestYes
Luminous Flux (lm)32
Max Input Power VA11 VA / 3 VA
MountingCeiling, Wall
Nominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassI
Temperature Range Min - Max (°C)-25...+35
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Wall mounting

  • Tables of 1 lux and 0,5 lux, under the Exit Light.
  • Level of measurement 0,02 m, measurement result with battery operation
R1 distance from wall, X axis
R4 distance from wall, Y axis

Wall mounting

Mounting height (m)Below the light (lx)R1 (m)R4 (m)R1 (m)R4 (m)
--1 lx1 lx0.5 lx0.5 lx
2141.22.31.52.7
2.591.431.63.2
361.53.11.83.5

Required products

Product codeElectrical numberDescription 
XWT52104244132Stamina wall bracket XWT5210Add to cart
XWT52114244133Stamina ceiling bracket XWT5211Add to cart

How to contact our sales teams

Teknoware Emergency Lighting distributors and sales offices around the world: