Products / Self Contained Systems / Emergency lights for escape routes / Solid, Line / Solid Line Lowbay Emergency Light Y4292WM
Solid Line Lowbay Emergency Light Y4292WM
Self-contained Escap Emergency light with 1 h Super Capacitor and Lumi Test Self-testing (Invidually packed TWS4292WM)
Solid Line Lowbay are designed for escape route emergency lighting. The luminaire is completely dust proof and water proof, so for example it is suitable for industrial premises and parking halls. Escap and centrally supplied luminaires are also suitable for outdoor use.
The Solid luminaire uses long lasting leds as its light source.
Special attention has been paid to the design, for easy installation.
Product code | Y4292WM | Electrical number (FI) | 4282347 | |
---|---|---|---|---|
GTIN | 6438045021713 | TARIC code | 94056180 | |
Weight | 1,50 kg | Measurements | 37,10 × 18,10 × 5,70 cm | |
Backup (h) | Yes | Body material | plastic | |
CE Mark | Yes | Colour | RAL9003 | |
Electrical Installation | 2/3 x 2,5 mm² | EN 1838 | Yes | |
EN 60598-2-22 | Yes | Escap | Yes | |
ETIM class | Emergency luminaire (EC001957) | Glow Wire Test of Plastic Materials (°C) | 850 | |
IP Class | IP65 | Light Source | LED | |
Lumi Test | Yes | Luminous Flux (lm) | 90 | |
Max Input Power VA | 3 VA | Mounting | Surface | |
Nominal Supply Voltage | 220-240 V, 50/60 Hz AC | Protection Class | II | |
Temperature Range Min - Max (°C) | -25…+35 | Suitable for Through-Wiring | Yes |
Product code | Y4292WM |
---|---|
Electrical number (FI) | 4282347 |
GTIN | 6438045021713 |
TARIC code | 94056180 |
Weight | 1,50 kg |
Measurements | 37,10 × 18,10 × 5,70 cm |
Backup (h) | Yes |
Body material | plastic |
CE Mark | Yes |
Colour | RAL9003 |
Electrical Installation | 2/3 x 2,5 mm² |
EN 1838 | Yes |
EN 60598-2-22 | Yes |
Escap | Yes |
ETIM class | Emergency luminaire (EC001957) |
Glow Wire Test of Plastic Materials (°C) | 850 |
IP Class | IP65 |
Light Source | LED |
Lumi Test | Yes |
Luminous Flux (lm) | 90 |
Max Input Power VA | 3 VA |
Mounting | Surface |
Nominal Supply Voltage | 220-240 V, 50/60 Hz AC |
Protection Class | II |
Temperature Range Min - Max (°C) | -25…+35 |
Suitable for Through-Wiring | Yes |
Scale Images
Light Distribution Charts
- 1 lux table for the centre line of an escape route, in accordance with EN 1838.
- Level of measurement 0.02 m, measurement results in emergency mode.
R1 distance from wall, X axis
R2 mounting distance, X axis
R4 distance from wall, Y axis
Emergency lighting for escape routes (ceiling mounting)
Mounting height (m) | Below the light (lx) | R1 (m) | R2 (m) | R4 (m) |
- | - | 1 lx | 1 lx | 1 lx |
2.5 | 2.5 | 7 | 16 | 1 |
3 | 1.5 | 8 | 18 | 1 |
Downloads and Data sheets
File name | Download |
---|---|
Product card | Download |
General information about installing Teknoware lights | Download |
Installation Guide Solid - VOT105 | Download |