Linespot II Lowbay emergency light TWT9971WT

24-230 V centrally supplied LED emergency light

The Linespot II Lowbay is a surface-mounted emergency light that is particularly suitable for low spaces. The luminaire’s optics are designed to provide a long and narrow light pattern that illuminates corridors and escape routes efficiently.
Thanks to the IP44 enclosure class, the Linespot II is also suitable for damp areas. The luminaire is easy and fast to install, thanks to a separate mounting base, which is also connected to the power supply.

icon-ce
EN 60598_2_22
650 °C
44
icon-LED
24-230 V 50/60 Hz AC DC
icon-ProtectionClassIII
icon-ProtectionClassII
9005
icon-Through-wiring
Product codeTWT9971WTElectrical number (FI)4148828
GTIN06438045029184TARIC code94056180
Weight0,50 kgMeasurements18,00 × 18,00 × 5,00 cm
Body materialplasticCE MarkYes
ColourRAL9005Electrical Installation2 x 2,5 mm² (24 V), 3 x 2,5 mm² (230 V)
EN 60598-2-22YesETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)650 IP ClassIP44
Light SourceLEDLuminous Flux (lm)230
Max Input Power VA8 VA (24 V), 10 VA (230 V)Max Input Power W5 W (24 V), 5 W (230 V)
MountingSurfaceMounting optionPendel
Nominal Supply Voltage24-230 V, 50/60 Hz AC, DCProtection ClassIII (24 V), II (230 V)
Temperature Range Min - Max (°C)-30...+50Suitable for Through-WiringYes
Product codeTWT9971WT
Electrical number (FI)4148828
GTIN06438045029184
TARIC code94056180
Weight0,50 kg
Measurements18,00 × 18,00 × 5,00 cm
Body materialplastic
CE MarkYes
ColourRAL9005
Electrical Installation2 x 2,5 mm² (24 V), 3 x 2,5 mm² (230 V)
EN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)650
IP ClassIP44
Light SourceLED
Luminous Flux (lm)230
Max Input Power VA8 VA (24 V), 10 VA (230 V)
Max Input Power W5 W (24 V), 5 W (230 V)
MountingSurface
Mounting optionPendel
Nominal Supply Voltage24-230 V, 50/60 Hz AC, DC
Protection ClassIII (24 V), II (230 V)
Temperature Range Min - Max (°C)-30...+50
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for escape routes (ceiling mounting)

  • 1 lux table for the centre line of an escape route, in accordance with EN 1838.
  • Level of measurement 0.02 m, measurement results in emergency mode.
R1 distance from wall, X axis
R2 mounting distance, X axis
R4 distance from wall, Y axis

Emergency lighting for escape routes (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R4 (m)
--1 lx1 lx1 lx
2.57.59211
4310281
61.59221

Accessories

Product codeElectrical numberDescription
TW77507B4281135Shock protecting cover TW77507BAdd to cart
TWT92024244125Wall bracket TWT9202Add to cart